Revista-SCLECARTO-Nº1-2019 - Flipbook - Página 17
Algoritmo de decisión en la reconstrucción acetabular
7. Jain S, Grogan RJ, Giannoudis PV. Options for managing severe
acetabular bone loss in revision hip arthroplasty. A systematic
review. Hip Int. 2014 Mar-Apr;24(2):109-22. Epub 2013 Oct 30.
8. D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF,
Boettcher WG, Steinberg ME, Stulberg SD, Wedge JH. ClassiÞcation
and management of acetabular abnormalities in total hip
arthroplasty. Clin Orthop Relat Res. 1989 Jun;243:126-37.
9. Paprosky WG, Perona PG, Lawrence JM. Acetabular defect
classiÞcation and surgical reconstruction in revision arthroplasty.
A 6-year follow-up evaluation. J Arthroplasty. 1994 Feb;9 (1):33-44.
10. Bradford MS, Paprosky WG. Acetabular defect classiÞcation: a
detailed radiographic approach. Semin. Arthroplasty 1995;6:76.
24. Berend ME, Berend KR, Lombardi AV, Cates H, Faris P. The
pacient-speciÞc Trißange acetabular implant for revisión total hip
arthroplasty in patients with severe acetabular defects: planning,
implnatation, and results. Bone Joint J 2018 Jan;100- B(1Supple
A):50-54.
25. Del Gaizo DJ, Kancherla V, Sporer SM, Paprosky WG. Tantalum
augments for Paprosky IIIA defects remain stable at midterm
followup. Clin Orthop Relat Res 2012;470:395–401.
26. Li H, Qu X, Mao Y, Dai K, Zhu Z. Custom acetabular cages offer
stable Þxation and improved hip scores for revision THA with
severe bone defects. Clin Orthop Relat Res 2016;474:731–740.
11. Sloof TJ, Huiskes R, van Horn J, Lemmens AJ. Bone grafting in total
hip replacement for acetabular protusion. Acta Orthop Scand
1984; 55:593-6.
27. Jenkins DR, Odland AN, Sierra RJ, Hanssen AD, Lewallen DG.
Minimun Þve year outcomes with porous tantalum Acetabular
Cup and Augment Construct in Complex Revision Total Hip
Arthroplasty. J Bone Joint Surg Am 2017 May 17;99(10):e49.
12. Schreus BW, Bolder SB, Gardeniers JW, Verdonschot N, Slooff TJ,
Veth RP. Acetabular revision wit impacted morselilled cancellous
bone grafting and a cemented cup. J Bone Joint Surg 2004;
86B:492-7.
28. Sporer SM, Bottros JJ, Hulst JB, Kancherla VK, Moric M, Paprosky
WG. Ace- tabular distraction: an alternative for severe defects
with chronic pelvic discontinu- ity? Clin Orthop Relat Res. 2012
Nov;470(11):3156-63.
13. Della Valle CJ, Berger RA, Rosenberg AG, et al. Cementless
acetabular reconstruction in revision total hip arthroplasty. Clin
Orthop Relat Res 2004;420:96.
29. Hasenauer MD, Paprosky WG, Sheth NP. Treatment options
for chronic pelvis discontinuity. J Clin Orthop Trauma 2018 JanMar;9(1):58-62.
14. Leopold SS, Rosenberg AG, Bhatt RD, et al. Cement- less acetabular
revision. Evaluation at an average of 10.5 years. Clin Orthop Relat
Res 1999;369:179.
30. Van Kleunen JP, Lee GC, Lementowski PW, Nelson CL, Garino JP.
Acetabular revisions using trabecular metal cups and augments. J
Arthroplasty. 2009;24 (Suppl. 6):64–68.
15. Della Valle CJ, Shuaipaj T, Berger RA, et al. Revision of the acetabular
component without cement after total hip arthroplasty. A concise
follow-up, at Þfteen to nineteen years, of a previous report. J Bone
Joint Surg [Am] 2005;87:1795.
16. Silverton CD, Rosenberg AG, Sheinkop MB, et al. Revision of the
acetabular component without cement after total hip arthroplasty.
A follow-up note regarding results at seven to eleven years. J Bone
Joint Surg [Am] 1996;78:1366.
17. Silverton CD, Rosenberg AG, Sheinkop MB, et al. Revision total
hip arthroplasty using a cementless acetabular component:
technique and results. Semin Arthroplasty 1995;6:109.
18. Sporer SM, Paprosky WG. The use of a trabecular metal acetabular
component and trabecular metal augment for severe acetabular
defects. J Arthroplasty 2006; 21 (6 Suppl 2): 83.
19. Flecher X, Sporer S, Paprosky W. Management of severe bone
loss in acetabular revision using a Trabecular Metal shell. J
Arthroplasty. 2008 Oct;23(7):949-55. Epub 2008 Mar 4.
20.Kosashvili Y, Backstein D, SaÞr O, Lakstein D, Gross AE. Acetabular
revision using an anti-protrusion (ilio-ischial) cage and trabecular
metal acetabular component for severe acetabular bone loss
associated with pelvic discontinuity. J. Bone Joint Surg Brit.
2009;91-B(7):870–876.
21. Ballester Alfaro JJ, Fernández JS. Trabecular Metal buttress
augment and the Trabecular Metal cup-cage construct in revision
hip arthroplasty for severe acetabular bone loss and pelvic
discontinuity. Hip Int. 2010;20.
22. Konan S, Duncan CP, Masri BA, Garbuz DS. The cup-cage
reconstruction for pelvic discontinuity has encouraging patient
satisfaction and functional outcome at median 6-year follow-up.
Hip Int. 2017;0.
23. Amenabar T, Rahman WA, Hetaimish BM, Kuzyk PR, SaÞr OA,
Gross AE. Promising mid-term results with a cup-cage construct
for large acetabular defects and pelvic discontinuity. Clin
Orthopaed Relat Res. 2016;474(2):408– 414.
Revista Sclecarto- N.º 1 - Año 2019 - 17